[🇵🇱 Polish version](README.md)
|
||
|
||
|
||
# TS0601_BY_RK.js
|
||
Minimalist Zigbee2MQTT converter for Tuya TS0601 TRV heads (ON / OFF)
|
||
|
||
## Why this converter exists
|
||
|
||
This converter was created to solve a real-world problem:
|
||
some Tuya TS0601 thermostatic radiator valves generate a huge amount of Zigbee reports, which:
|
||
|
||
- spam MQTT
|
||
- cause constant state changes in Home Assistant
|
||
- increase CPU usage and database load
|
||
- destabilise automations
|
||
- provide no real value in everyday use
|
||
|
||
In installations with many TRVs (a dozen or more), this resulted in:
|
||
- Home Assistant slowdowns
|
||
- difficult troubleshooting
|
||
- unpredictable automation behaviour
|
||
|
||
## Conscious design decision
|
||
|
||
Instead of fighting every reported variable, a different approach was chosen:
|
||
|
||
minimalism over completeness
|
||
|
||
This converter:
|
||
- removes all unnecessary exposes
|
||
- ignores temperature, mode, and calibration reports
|
||
- reduces control to a single simple action: ON / OFF
|
||
|
||
Result:
|
||
- minimal Zigbee traffic
|
||
- no MQTT spam
|
||
- stable Home Assistant
|
||
- predictable automations
|
||
|
||
## How the converter works
|
||
|
||
Tuya TS0601 TRVs are controlled using datapoint DP=2 (setpoint).
|
||
|
||
Mapping:
|
||
- ON -> sends 45°C (valve forced fully open)
|
||
- OFF -> sends 0°C (valve fully closed)
|
||
|
||
Any other value:
|
||
- is treated as ON
|
||
- is not corrected back to avoid generating additional Zigbee traffic
|
||
|
||
The state is published immediately after sending the command, without waiting for further device reports.
|
||
|
||
## What is NOT exposed (by design)
|
||
|
||
This converter deliberately does NOT expose:
|
||
- target temperature
|
||
- operating modes
|
||
- calibration or offsets
|
||
- diagnostic data
|
||
|
||
This is not a bug or missing feature — it is a deliberate limitation to ensure system stability.
|
||
|
||
## Exposed features
|
||
|
||
- Switch (ON / OFF) – main valve control
|
||
- Battery (%) – if reported by the device
|
||
- Local temperature (°C) – passive only
|
||
|
||
## How to add the converter to Zigbee2MQTT
|
||
|
||
1. Copy the file TS0601_BY_RK.js to the Zigbee2MQTT directory, for example:
|
||
/zigbee2mqtt/external_converters/TS0601_BY_RK.js
|
||
|
||
If the external_converters directory does not exist, create it.
|
||
|
||
2. In /zigbee2mqtt/configuration.yaml add:
|
||
```
|
||
external_converters:
|
||
- TS0601_BY_RK.js
|
||
```
|
||

|
||
|
||
3. Restart Zigbee2MQTT
|
||
|
||
## How to add a new TRV (fingerprint)
|
||
|
||
If your TS0601 TRV is not supported, you need to add its identifier.
|
||
|
||
1. In Zigbee2MQTT, check:
|
||
- modelID
|
||
- manufacturerName
|
||
|
||
Example:
|
||
modelID: TS0601
|
||
manufacturerName: _TZE200_xxxxxxxx
|
||
|
||
2. In TS0601_BY_RK.js add a new fingerprint entry:
|
||
```
|
||
{ modelID: 'TS0601', manufacturerName: '_TZE200_NOWYID' }
|
||
```
|
||
<img width="1371" height="1282" alt="add new trv" src="https://github.com/user-attachments/assets/f1e24681-78da-4464-8183-a78c7d2229dd" />
|
||
|
||
3. Restart Zigbee2MQTT
|
||
|
||
## Who this converter is for
|
||
|
||
- installations with many TRVs
|
||
- systems sensitive to MQTT spam
|
||
- simple open / close valve control
|
||
- stable and predictable automations
|
||
|
||
It is NOT intended for users who expect full temperature control from Home Assistant.
|
||
|
||
## Summary
|
||
|
||
This converter does not try to be perfect.
|
||
Its goal is stability, silence, and predictable behaviour.
|